Controval
Product group

Valves and actuation

Manual, automated and control valves, with the actuators, positioners and accessories that operate them. We supply them alone, as spares for your installed base, or assembled and tested as one unit inside our skids.

At a glance

We select, assemble, test and support the valve and everything that moves it.

  • Valve, actuator and accessories assembled and tested as one unit
  • Valve data report prepared by our engineers for control valves
  • Supplied alone, as spares, or integrated into skids and panels
  • Installation, commissioning and aftermarket support
01

Automated valves

An automated valve is a valve body with an actuator, and often a panel, that opens or closes it on a signal or on a loss of power. They are used where operators cannot or should not reach the valve by hand, and where a defined failure position matters.

Request a quote
Valves assembled with actuators in our workshop

Electric

Motor-driven actuator. Needs only power and a signal, so it suits sites with no air or gas supply and long stroking times. Slower than pneumatic or hydraulic, and fail-safe action needs a spring or battery backup. Digital communication such as Profibus and Modbus is available for multi-turn and linear actuators.

Low-pressure pneumatic

Spring-return or double-acting actuator on instrument air. Simple, fast and common in plants with a clean air system. Fail-safe position comes from the spring; size grows quickly on large, high-torque valves.

High-pressure gas hydraulic

Uses line or bottled gas pressure to drive a piston, often with a hydraulic stage for smooth motion. Suited to remote pipeline sites with no electricity or air. Needs gas that is clean and dry enough for the actuator. Gas-over-oil and self-contained hydraulic designs are available.

Direct gas

Process or pipeline gas operates the actuator directly, with no compressor or power. Good for remote, unpowered locations. Gas is vented or used with each stroke, and supply quality and pressure must be checked.

Electrohydraulic

A self-contained electric pump and hydraulic cylinder in one package. Gives high thrust and a spring or accumulator fail-safe with only electrical power. More complex and heavier than a pneumatic actuator.

Hydraulic power units

A central skid supplies hydraulic pressure to one or several actuators. Fits sites with many valves or very high force. It adds a package to maintain, which is why we also build these as skids.

Valves we automate

Quarter-turn valves (ball, plug, butterfly) and multi-turn valves (gate, globe, knife), for air, liquid, gas and crude oil.

Package accessories

Line breaks, partial stroke test devices, speed regulating valves, storage tanks, position indicators and valve positioning devices. We also supply video cameras for monitoring and safety, and air accumulator tanks.

Installation and training

We install actuators at our facilities or yours, or retrofit them in the field. On-site and in-house training and yearly after-sales maintenance contracts are available.

  • Shutdown valves (SDV) that isolate a section on an emergency signal
  • Blowdown valves (BDV) that depressurize equipment
  • On/off isolation on skids, wellheads, pipelines and tank farms
  • Remote or automatic sequencing from a PLC or DCS
  • Pressure (PCV), level (LCV) and flow (FCV) control valves, as well as on/off and control duty
  • Valve type, size, pressure class and body material
  • Process fluid, operating and design pressure and temperature
  • Required failure position (open, closed or last position) and stroking time
  • Available power, instrument air or gas supply, and its quality
  • Control signal, feedback needed and any hazardous area rating

We size the actuator to the valve torque and the failure position you need, assemble the valve, actuator and accessories, and test them as one unit. We can integrate them into a skid or panel, commission them on site and supply spares.

BrandsLimitorqueFlowserveWestlockVersa
02

Manual valves

Manual valves are operated by hand with a handwheel, lever or gearbox. They isolate, throttle or direct flow and protect equipment from backflow. The right choice depends on the fluid, pressure, temperature and how often the valve is operated.

Request a quote
Gate valves in our workshop

Gate

Full-bore, straight-through flow with low pressure drop. Meant for fully open or fully closed use, not throttling. Slow to operate, and a partly open gate wears the seats.

Globe

Good throttling and tight shutoff. The flow path causes a higher pressure drop than gate or ball valves. Common on steam, drains and bypass lines.

Ball

Quarter-turn, quick, with tight shutoff and low pressure drop. Widely used for on/off. Not ideal for throttling because partly open seats can wear.

Butterfly

Compact and light, quarter-turn disc in the flow. Economical for large lines at moderate pressure. The disc stays in the flow, so pressure drop and sealing limits apply.

Check

Lets flow pass one way and closes on reverse flow, with no operator. Swing, lift, dual-plate and other designs differ in response speed and pressure drop. Protects pumps and compressors.

Needle

Fine, precise adjustment of small flows through a tapered stem. Used on instrument lines, sampling and gauge isolation. Low capacity, and not for large flows.

Plug

Quarter-turn with a tapered or cylindrical plug. Handles slurries, dirty fluids and multi-port diversion. Some lubricated types need regular sealant maintenance.

  • Line isolation and maintenance block valves
  • Drains, vents and instrument root valves
  • Pump suction and discharge, with check valves on discharge
  • Corrosive, high-temperature or high-pressure service with the proper materials
  • Fluid, concentration and contaminants such as H2S, CO2 or solids
  • Size, pressure class, end connections and applicable standard
  • Operating and design temperature
  • Body, trim and seat materials required, or NACE and similar requirements
  • Operation: handwheel, lever or gear, and expected cycle frequency

We select valves to the standards and service conditions of your application, including corrosive fluids and high temperatures. We supply them alone, as spares for your installed base, or fitted into skids and piping packages. Our range includes valves made to API for daily use, and valves designed for high-risk, high-performance service: metal seats, special coatings, seal tightness and extreme services.

BrandsFlowserveCameronMokveldFBVWilliams Valves
03

Control valves

A control valve changes flow, pressure or level by varying its opening in response to a controller. Performance depends on correct sizing, trim and actuator, so we start with a valve data report before choosing the valve.

Request a quote
Control valve with actuator and accessories

Globe

The standard for control. Good rangeability and a wide choice of trim for noise, cavitation or erosion. Heavier and costlier than rotary valves, with lower capacity per size.

Ball

Rotary valve with high capacity and tight shutoff. Characterized balls and segment valves give usable control. Suits viscous or fibrous fluids, with less trim choice than globe valves.

Butterfly

Compact, light and economical for large lines at low pressure drop. Limited rangeability and control near closed. High-performance designs extend the pressure and shutoff range.

Metal or soft seat

A metal seat tolerates high temperature, erosion and abrasion but leaks more at shutoff. A soft seat (PTFE or elastomer) seals tightly but has temperature and wear limits. Pick by the leakage class you need. Metal seats can have a lapped finish.

Pneumatic or electric actuator

Pneumatic actuators are fast and give simple fail-safe action with a spring. Electric actuators need no air and suit remote sites but are slower and need a plan for failure position.

  • Flow, pressure and level control loops
  • Separator level and pressure control
  • Pump recirculation and minimum flow
  • Temperature control through heat exchangers and heaters
  • Flow, inlet and outlet pressure at minimum, normal and maximum, with temperature
  • Fluid, density or specific gravity, viscosity and vapor pressure
  • Line size, pressure class and body materials
  • Allowable noise level, leakage class and failure position
  • Control signal, air supply and whether a positioner or other accessories are needed

We prepare the valve data report (type, size, trim, material, actuator) from your process data and supply the valve with metal or soft seat. We assemble it with positioner and accessories, test it as one unit and support commissioning. Parts are interchangeable across several options, from clean service to harsh corrosive or erosive service. Accessories include solenoids, switches and stroke test devices.

BrandsSamsonFlowserveKimrayMokveld
04

Solenoid and pilot valves

A solenoid valve uses an electric coil to open or close a small flow path. It is the usual link between a control system and air, gas or fluid that moves an actuator. Choosing the right operating principle avoids sticking and weak operation.

Request a quote
Actuated valve with solenoid and accessories

Direct-acting

The coil lifts the seal directly. Works from zero pressure and responds fast. Orifice size is limited by coil force, so flow is small and high pressures need a stronger coil.

Internally piloted

Line pressure helps move the main seal, so a small coil can control larger flow. Needs a minimum pressure difference across the valve to open and stay open.

Externally piloted

A separate pilot supply moves the main valve, which suits low or variable line pressure. Needs an extra supply line and can add a failure point.

Manifold mounting

Several valves share one base, which cuts fittings and leak points and saves space. Good for skids and panels, but replacing one valve means working on a shared base.

  • Switching air to a pneumatic actuator on a shutdown valve
  • Pilot control of larger valves and regulators
  • Process loops with small flows of air, gas, water or oil
  • Machine builders (OEM) and skids with many valves on one manifold
  • Medium (air, gas, water, oil) and its cleanliness
  • Port size, number of ways and normal state (open or closed)
  • Pressure range and flow needed
  • Coil voltage, power limits and area classification
  • Mounting: line, manifold or on an actuator

We select coil voltage, ports, body materials and area ratings to match your actuator and control system. We supply them alone or mounted and tubed on skids and panels that our own engineers build.

BrandsVersa
05

Positioners

A positioner compares the signal from the controller with the real position of the valve stem or shaft, and adjusts the air to the actuator until they match. It corrects for friction and supply changes so the valve does what the controller asks.

Request a quote
Valve positioner

Pneumatic or electrical signal

Pneumatic positioners take a 3 to 15 psi signal. Electropneumatic ones take 4 to 20 mA, and digital models add HART or fieldbus and diagnostics. Digital units cost more but reveal friction and travel problems.

Modulating service

Positioners suit continuous throttling duty. They use some instrument air at all times and need clean, dry supply. For simple on/off duty, a solenoid and limit switch is usually enough.

Single and double acting

Single-acting positioners work spring-return actuators. Double-acting ones drive both sides of a piston and fit larger or spring-less actuators.

  • Modulating control valves where accurate position matters
  • Valves with high friction, packing load or large actuators
  • Split-range control and speed-up of slow actuators
  • Diagnostics of valve and actuator health with digital positioners
  • Control signal (pneumatic, 4 to 20 mA, HART or fieldbus)
  • Actuator type: linear or rotary, single or double acting
  • Air supply pressure and quality
  • Area classification and mounting standard
  • Need for position feedback or diagnostics

We select and mount the positioner to match your valve and actuator, set it up and calibrate it with the valve before delivery. We support site commissioning and spare units.

06

I/P converters

An I/P (current to pressure) converter turns a 4 to 20 mA signal into a proportional air pressure, typically 3 to 15 psi. It lets an electronic controller drive pneumatic equipment that has no positioner of its own.

Request a quote
I/P converter mounted next to a control valve

Current to pressure

Converts 4 to 20 mA into a linear pressure output. Accuracy and flow are lower than with a positioner, and it does not correct for valve friction. Good for small volumes or as the input to a positioner.

Open loop

An I/P sets pressure, not position. If valve friction or load changes, the valve position shifts. Where position accuracy matters, use a positioner.

Supply and mounting

Needs clean, dry, regulated instrument air. Choose the housing and area rating for the site, and mount away from heavy vibration.

  • Driving a pneumatic actuator from a DCS or PLC output
  • Feeding a positioner with a pneumatic signal
  • Controlling dampers, louvers and small pneumatic devices
  • Retrofits where plant control is electronic but valves are pneumatic
  • Input signal (typically 4 to 20 mA) and output range
  • Supply air pressure and required flow
  • Area classification and enclosure rating
  • Mounting: pipe, wall or on the actuator
  • What it will drive: actuator, positioner or damper

We select the converter for your signal, pressure range and area rating. We supply it alone or tubed to the valve, with spares for your installed base.

07

Limit switches and position monitors

These devices show and report whether a valve is open or closed. They give the control room confirmation that a command was carried out, and give operators a visual check at the valve itself. They mount on the actuator and do not touch the process.

Request a quote
Technician fitting limit switches on an actuator

Snap switch

Mechanical contacts operated by a cam on the valve shaft. Simple, robust and low cost. Contacts wear and can fail from vibration or moisture, so enclosure choice matters.

Proximity

Non-contact inductive sensors sense a target on the shaft. No moving contacts to wear, so they suit vibration and frequent cycling. They need correct power wiring and, in hazardous areas, an approved barrier.

Partial stroke

Moves a shutdown valve a small part of its travel to prove it can move, without stopping the process. Helps find stuck valves between full tests. It does not replace full stroke testing.

Local indicator and remote HMI

A visible indicator on the valve and a signal to the control system for the HMI. Operators can see status in the field and in the control room.

  • Open and closed confirmation for shutdown and isolation valves
  • Interlocks and sequencing in a PLC or DCS
  • Local visual indication for operators on rounds
  • Partial stroke testing of safety valves without full shutdown
  • Valve and actuator type, and mounting pattern (such as NAMUR)
  • Signals needed: open, closed, intermediate or analog position
  • Contact or proximity type and power supply
  • Area classification and enclosure rating
  • Whether partial stroke testing is required

We select and mount the switches or monitors on your actuators, wire them and test them with the valve. We can bring the signals to your panel or PLC and commission the full loop.

BrandsWestlock
FAQ

Common questions

Can you supply the valve, actuator and accessories together?

Yes. We assemble the valve with its actuator, positioner, solenoid, limit switches and tubing, and test them as one unit. You receive a single package instead of parts to match on site.

How do I choose between electric, pneumatic and hydraulic actuators?

Start with the available utilities and the failure position. Pneumatic is fast and simple where instrument air exists. Electric suits sites with power only. Gas or hydraulic suits remote, high-force or unpowered sites. Stroking time and torque finish the choice.

What do you need to size a control valve?

Flow, pressures and temperature at minimum, normal and maximum cases, plus fluid properties, line size and pressure class. From these we prepare the valve data report with type, size, trim, material and actuator.

Do you supply spares for valves we already have?

Yes. We support installed valves, actuators and accessories with spares and replacements. Send us the tag, nameplate data or a photo and we will work out the match.

Looking for a complete system?

See how we integrate these products into skids, built and tested in our workshops.

Get a quoteSkids