Controval
Product group

Insulation and fireproofing for equipment, pipes, valves and actuators

Thermal and fire protection engineered for the equipment you already run, from removable blankets on hot valves to fire jackets on actuators and cable boxes. We design, make and install it, and most of it can be fitted without stopping the process.

At a glance

We engineer, make and install thermal and fire protection for plant equipment.

  • Removable blankets and jackets cut to your valve, flange or actuator
  • Freeze protection for lines, instruments and sample points
  • Fire protection retrofitted to existing plants without stopping the process
  • Supply, installation and replacement when the insulation wears out
01

Insulation

Insulation holds heat in, keeps cold out, protects people from hot surfaces and cuts noise. On valves, flanges, pumps and instruments the shape is irregular, so removable, custom-fitted covers are often more practical than rigid pipe insulation.

Request a quote
Insulation blanket on a valve

Insulation blankets

Removable covers with an insulating core and a protective outer layer, cut to the shape of a valve, flange or instrument. They fasten on and come off in minutes. Best where equipment needs regular access. The cover has to be sized to the real component, so we measure first.

Fire blankets

Covers made from heat-resistant fabrics that shield equipment from short exposure to flame or radiant heat, and also protect people near hot work. They are a temporary or supplementary measure, not a replacement for permanent fireproofing where a rated system is required.

Acoustic curtains

Sound-absorbing and sound-blocking panels hung or fitted around noisy equipment such as compressors, generators and vents. They lower noise at the source or at the boundary. Results depend on the noise frequency and on how well the enclosure is sealed.

Freeze protection

Insulation combined with heat tracing (electric or steam) keeps lines, instruments and sample points above the freezing or gelling temperature of the fluid. Good design needs the minimum ambient temperature, the required maintain temperature and the heat loss of the piece being protected.

Thermal shields

Removable shields that protect people and nearby equipment from hot surfaces and radiant heat.

Leak protection

Covers and shields that contain or deflect leaks and spray at flanges and joints.

  • Hot valves, flanges and pump casings that need personnel protection or heat retention
  • Heat-traced lines and instruments in cold climates or outdoor skids
  • Compressors, engines and vents where noise has to come down
  • Equipment that must be uncovered often for inspection or maintenance
  • Equipment to cover (valve, flange, pump, instrument) with size and tag
  • Operating and maximum surface temperature
  • Minimum and maximum ambient temperature, indoor or outdoor
  • Need for easy removal and how often it will be removed
  • Exposure to oil, water, chemicals, UV or washdown

We engineer the cover to your equipment, make it, and install it on site. We can also replace worn insulation on equipment we supplied and tie freeze protection into skids we build. We have made covers for many industries, to our customers' designs, specifications and techniques.

02

Fireproofing

Fireproofing keeps critical equipment working long enough for a safe shutdown or for the fire to be controlled. It matters most for emergency shutdown valves, their actuators and the cables and boxes that signal them. Fires and explosions endanger people, destroy installations and damage the environment. Protecting actuators helps keep control of the automation in an emergency and supports a safe, sequenced shutdown, with less downtime. The result is reduced downtime and reduced insurance rates, saving your facility money.

Request a quote
Fire-protection jackets on actuators

Jackets

Fitted fire-resistant covers that wrap valves, actuators and instruments. They can be installed on existing equipment and removed for maintenance. Best for retrofits where access is needed. Check that the jacket does not block actuator venting or travel indicators.

Coatings

Intumescent or cementitious coatings are applied to surfaces and cable trays. Intumescent products swell under heat to form an insulating layer. Coatings need clean surface preparation and curing time, and are harder to remove for maintenance than a jacket.

Actuators and boxes

Protection for the parts that make a valve fail safe: actuators, positioners, solenoids, limit switches and junction boxes. The goal is to keep the valve and its signals working for the time the fire study requires. Heat build-up inside the cover must also be considered.

  • Emergency shutdown and blowdown valves that must still move during a fire
  • Actuators, solenoids and junction boxes near hydrocarbon equipment
  • Cable runs and trays that carry safety and control signals
  • Existing plants where a new fire study calls for more protection
  • Equipment and tags to protect, with photos or drawings
  • Required fire rating or protection time, and the standard or site spec
  • Fire type: hydrocarbon pool or jet fire
  • Operating temperature and ambient conditions
  • Whether the plant can be shut down or the work must be done online

We supply fire protection fitted to existing installations without stopping the process, and to valves and actuators we assemble in our own shops. We help you match the product to the protection time your fire study or site standard asks for.

FAQ

Common questions

Can insulation or fireproofing be installed while the plant is running?

Often yes. Removable blankets and jackets are fitted from outside the equipment. Coatings and work near live hot surfaces depend on your site safety rules and permits.

Is a fire blanket the same as fireproofing?

No. A fire blanket gives short, limited protection and is mainly used for hot work and temporary cover. Fireproofing is a designed system selected for a stated protection time.

Do removable covers lose heat at the joints?

Some, yes. A well-cut blanket with overlaps and tight fasteners performs close to fixed insulation, but small gaps matter. Measuring the real component helps.

What do you need to quote a cover?

The equipment type and size, operating temperature, ambient range and the protection goal: heat retention, personnel protection, noise, freeze or fire. Photos and dimensions speed things up.

Looking for a complete system?

See how we integrate these products into skids, built and tested in our workshops.

Get a quoteSkids